Power Transformer

https://www.tmadrive.com/web/image/product.template/4/image_1920?unique=766367c
Efficient, grid-ready Power Transformers delivering stable performance and reduced lifecycle cost. 

• “Fire‑safe indoor transformers for data centers, metros, hospitals, and commercial towers — up to 33 kV.”

• “Cast‑resin dry‑type transformers: low maintenance, low smoke, high reliability for critical infrastructure.”

• “Designed to IS/IEC 60076‑11 with PD ≤ 10 pC, AN/AF cooling, and IP‑rated enclosures.”


Specifications

TypeDry Type (VPI/CRT)/ Oil Cooled
Voltage RatingUp to 33KV
Power Rating10KVA to 2.5MVA
Insulation ClassF Class for dry type (H Class on request)
A Class for Oil Cooled
Cooling
AN/AF/ONAN/ONAF
Applicable StandardsIEC 60076, IS 2026
CertificationsCE, ROHS

₹ 0.00 0.0 INR ₹ 0.00


This combination does not exist.

Dry-type (Cast-Resin / VPI)

  • Commercial & public buildings: malls, hospitals, airports, hotels, high-rises (indoor rooms, low fire load).
  • Data centers & IT campuses: UPS/inverter isolation, LV/MV step-down near white space.
  • Industries (indoor zones): pharma, food, beverages, textiles, electronics/semiconductor, cleanrooms.
  • Transport infrastructure: metro/rail stations, tunnels, underground facilities (E2/C2/F1 focus).
  • Education & healthcare campuses: labs, imaging suites, research buildings.
  • OEM/machine integration: inside large machinery skids, test benches, E-house containers.
  • Sensitive environments: museums, theaters, studios (low noise, no oil containment). 
  • Marine onshore facilities: cruise terminals, shipyards (indoor substations).

Oil-immersed (Mineral or Natural-Ester)

  • Heavy industry: steel/cement/paper/sugar/chemicals—plant step-down, process substations, outdoor duty.
  • Generation & microgrids: plant auxiliaries in thermal, hydro, captive cogeneration
  • DG sets step-up/aux.
  • Renewables (plant side): solar/wind inverter step-up, collector transformers, pad-mount/skid units.
  • Oil & gas / petrochemical: refineries, tank farms, pipelines, FPSO topside auxiliaries (often ester for fire safety).
  • Mines & minerals: pit-head substations, long cable feeders, harsh outdoor environments.
  • Ports & airports (airside): apron lighting, shore-power, cranes/RTGs.
  • Water & wastewater: treatment plants, desalination (outdoor/corrosive atmospheres).
  • Traction & rail yards: depot substations, aux supplies.
  • Agro/irrigation & remote sites: pump stations, farm/process clusters.

Dry Type Transformers -Myths vs Facts

• “Dry‑type can’t handle humidity.” — Fact: cast‑resin with proper IP enclosure works well in high humidity; sealing & heaters help in standby sites.

• “They’re always noisier than oil‑filled.” — Fact: modern designs meet low‑noise specs; AF mode can be the limiter — verify dB(A) at 1 m.

• “Maintenance‑free.” — Fact: no oil work, but you still inspect, clean vents, check fans/terminals, and trend PD/thermal health.

Selection Quick‑Help

• Define the space: room size, ventilation, access routes, floor loading; pick enclosure & IP early.

• Confirm duty: continuous vs cyclic, overload profile, ambient; decide AN vs AF and temperature class (F/H).

• EMC & harmonics: declare %THD and presence of large VFDs; choose K‑factor or isolation with electrostatic screen.

• Fire & codes: confirm local approvals; low smoke/halogen‑free preference for airports/hospitals/tunnels.

• Serviceability: specify space for coil inspection, fan replacement, and terminal access (front/top).